<< To Portfolio List
ZERUST® Zerion® FAN-6 powder being top-dressed onto the exposed sand bed

Protecting a 38-Foot-Diameter Storage Tank Floor with ZERUST® Zerion® FAN-6

ZERUST® Zerion® FAN-6 Corrosion Inhibitor Powder

Project Specifics

Installation Date
February 2023

Location
Illinois, USA

Environmental Conditions
Cloudy with rain, about 35 °F, 70% humidity

Asset Details
Aboveground storage tank, 38-ft diameter

Vessel Construction
Single bottom, out of service, 4-in. sand foundation with liner, no slope

Inhibitor Delivery System (IDS)
None

Zerust Product(s) Used
ZERUST® Zerion® FAN-6 Corrosion Inhibitor Powder

Project Details:

The original tank floor was removed for replacement, leaving the sand base exposed and the tank roof absent. ZERUST Integrity Solutions® top-dressed ZERUST® Zerion® FAN-6 powder over the sand bed with a spreader at about 400 g/m². Rain halted work after part of the bed was treated, and a metal sheet covered the treated area until the weather cleared.

Outcome & Recommendations:

The installation team was to finish the application once the weather cleared, then install the new tank floor. ZERUST Integrity Solutions® recommends sealing the chime area with polyurethane construction adhesive at that stage.