Project Specifics
Installation Date
February 2023
Location
Illinois, USA
Environmental Conditions
Cloudy with rain, about 35 °F, 70% humidity
Asset Details
Aboveground storage tank, 38-ft diameter
Vessel Construction
Single bottom, out of service, 4-in. sand foundation with liner, no slope
Inhibitor Delivery System (IDS)
None
Zerust Product(s) Used
ZERUST® Zerion® FAN-6 Corrosion Inhibitor Powder
Project Details:
The original tank floor was removed for replacement, leaving the sand base exposed and the tank roof absent. ZERUST Integrity Solutions® top-dressed ZERUST® Zerion® FAN-6 powder over the sand bed with a spreader at about 400 g/m². Rain halted work after part of the bed was treated, and a metal sheet covered the treated area until the weather cleared.
Outcome & Recommendations:
The installation team was to finish the application once the weather cleared, then install the new tank floor. ZERUST Integrity Solutions® recommends sealing the chime area with polyurethane construction adhesive at that stage.